wM-Bus/OMS Radio Protocol
As long as the Node is not paired with an energieleser.bridge, it sends each assigned port as its own wM-Bus meter: in C1 mode (frame format A) on 868.95 MHz, encrypted with OMS security mode 5 (AES-128-CBC). This page is for anyone adding the Node to their own wM-Bus receiver, for example another manufacturer's gateway. How to assign the ports with the button is described under Pairing with an External Device.
Applies to Node firmware 1.6.1.
When does the Node send wM-Bus?
| Node state | What it sends |
|---|---|
| No port assigned | Only a pairing signal for the Bridge, no wM-Bus telegram |
| Ports assigned with the button, not paired with the Bridge | One wM-Bus/OMS telegram per assigned port |
| Paired with the Bridge | No more wM-Bus, but the Bridge's proprietary telemetry protocol |
As soon as the Node is paired with a Bridge, wM-Bus operation stops. To return to wM-Bus operation, reset the Node (hold the button for 10 seconds) and assign the ports again with the button.
Radio parameters
| Property | Value |
|---|---|
| Mode | C1 (meter → receiver), transmit only |
| Frame format | A |
| Frequency | 868.95 MHz |
| Data rate | 100 kcps, 2-FSK |
| Transmit power | up to +14 dBm |
| C field | 0x44 (SND-NR) |
| Transmit interval | 5 minutes on battery, 1 minute on USB-C power |
| Telegrams per interval | 1 per assigned port |
The Node does not receive wM-Bus commands from external devices. Bidirectional modes (C2, T2, S2) and the T1 and S1 modes are not supported.
Addressing
Each port appears as its own meter with its own address:
| Field | Content |
|---|---|
| Manufacturer (M field) | Bytes 0xAA 0x55 (provisional value, will change to a registered code) |
| Identification number (A field) | 8 BCD digits: the first 7 digits are the Node ID as a decimal number (its last 7 digits), the last digit is the port (1–4) |
| Version | 0x18 |
| Device type | Gas 0x03, water 0x07, electricity 0x02, heat 0x04 |
Example: the Node with ID DDA151 (decimal 14524753) sends port 3 under identification number 45247533.
Encryption
| Property | Value |
|---|---|
| Security mode | OMS mode 5, AES-128-CBC |
| Key | The AES key on your Node, the same for all four ports |
| IV | Per OMS mode 5: manufacturer, identification number, version, device type and 8 × access number |
| Check bytes | The decrypted content starts with 0x2F 0x2F |
| Additional layers | None (no ELL, no AFL, no key derivation) |
The access number increases by one per port with every telegram.
Telegram structure and data records
Gas, water and electricity via pulse send a short telegram (CI 0x7A, 31 bytes, one encrypted block). Electricity via TTL and heat send a long telegram (CI 0x72) containing only the values the meter actually provides.
| Meter type | CI | Data records (DIF VIF) | Content |
|---|---|---|---|
| Gas (pulse) | 0x7A | 0C 13 | Meter reading, 8 BCD digits |
| Water (pulse, sensor or TTL reading head) | 0x7A | 0C 13 | Meter reading, 8 BCD digits |
| Electricity (pulse) | 0x7A | 04 03 | Meter reading, 32 bit |
| Electricity (TTL) | 0x72 | 04 03 | Import in Wh |
| 04 81 3C | Export in 0.01 Wh | ||
| 04 2B | Power in W | ||
| Heat (TTL, port 1 or 2) | 0x72 | 04 03 | Energy in Wh |
| 04 13 | Volume in l | ||
| 04 2B | Power in W | ||
| 04 3B | Flow in l/h | ||
| 02 5A | Flow temperature in 0.1 °C | ||
| 02 5E | Return temperature in 0.1 °C |
A port with a TTL reading head only sends after it has read the meter successfully once. A port without an assignment never sends.
Up to and including firmware 1.6.1, for gas, water and electricity via pulse the Node sends the reading in whole m³ or whole kWh, although the VIF states litres (0x13) or Wh (0x03). Multiply the value by 1000 in your receiver. Electricity via TTL and heat are not affected.
Compatibility
The telegrams follow the simplified OMS structure above. Time stamps, status messages and due-date values are not included. The Node has not yet been officially tested with other manufacturers' receivers. If you have questions, write to info@energieleser.de.